Updated

How to Measure Noise Levels in the Workplace

Published

Try It

Questions

What instrument is used to measure workplace noise?+

A sound level meter for spot readings and screening, and a noise dosimeter, worn by the worker, for the full-shift exposure. OSHA calls the dosimeter the primary instrument for compliance measurements.

What settings should a sound level meter use for workplace noise?+

A-weighting and slow response, which is how OSHA's limits are measured. A Type 2 meter is the minimum precision OSHA requires, with an accuracy of plus or minus 2 dBA.

When does an employer have to measure noise?+

Under OSHA's standard, when any worker's exposure may equal or exceed an 85 dBA 8-hour time-weighted average. The employer then needs a monitoring program and must repeat it when changes raise the noise.

Where should the microphone be placed?+

In the worker's hearing zone, which OSHA defines as a 2-foot-wide sphere around the head. A dosimeter microphone goes on the shoulder, pointing straight up.

Can I measure workplace noise with my phone?+

For a first check, yes. For compliance, use a Type 2 sound level meter or a dosimeter. NIOSH says its app meets Type 2 requirements only with a calibrated external microphone.

Sources

Every figure on this page comes from these sources.

See all guides